RESPONSETIME report

 

Bucket-specific screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D016ZE04 SM2 RESPONSETIME (BUCKETS)

CYCLE:

120 S

 

99-03-24

14:30:00

 

 

*GLOBAL

 

APPLICATION: *ALL

 

 

 

 

 

 

 

 

 

 

 

PARTNER:

 

*ALL

 

 

 

 

 

 

 

 

 

CONN-TYPE:REMOTE

PROCESSOR:

*ALL

 

 

 

 

 

 

 

 

 

---------------------------

 

+

----------------

+----------------

 

+----------------

 

+

 

RESP. TIME (1)

THINK TIME

TRANS. TIME

WAIT TIME

 

+----------------

 

+

----------------

+----------------

 

+----------------

 

+

 

BUCKET

COUNT

BUCKET

COUNT

BUCKET

COUNT

BUCKET

COUNT

 

+----------------

 

+

----------------

+----------------

 

+----------------

 

+

 

0.5

4523

5.0

4461

0.5

4482

0.1

71

 

1.0

9

15.0

80

1.0

18

0.2

0

 

2.0

10

30.0

19

2.0

16

0.5

0

 

5.0

27

60.0

14

5.0

35

1.0

0

 

10.0

14

120.0

7

10.0

12

2.0

0

 

>

10.0

19

> 120.0

15

>

10.0

28

>

2.0

0

 

----------+----------------

 

+

----------------

+----------------

 

+----------------

 

+

 

AVG SEC

 

0.1

 

0.6

0.1

 

 

0.0

 

NR. INTER

4583

4581

4563

 

 

71

 

RATE 1/SEC

38.2

38.2

38.0

 

 

0.6

 

----------+----------------

 

+

----------------

+----------------

 

+----------------

 

+

 

INPUT-LEN:472.8

OUTPUT-LEN:551.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

For each screen, the associated connections or connection groups are output above the monitoring data, as well as the connection set name ("GLOBAL" is the name given in the example), when the ADD-CONNECTION-SET statement is defined).

CONN-TYPE

Types of connections taken into account during monitoring:

 

REMOTE:

Remote connections only

 

LOCAL:

Local connections only

 

BOTH:

Local and remote connections

RESP. TIME (1)

Response time data; the type of response time monitored (as

 

specified via the DEFINITION operand of the SET- and MODIFY-

 

RESPONSETIME-PARAMETER statements) is output

 

(1):

Response time as per definition 1

 

(2):

Response time as per definition 2

THINK TIME

Think time data

 

TRANS. TIME

Transaction time data

 

WAIT TIME

Wait time data (in the BCAM pool)

AVG SEC

Average duration of an interaction in seconds (without overflow

 

data)

 