RESPONSETIME report

SM2 reports

NR. INTER

Total number of interactions in the monitoring cycle (without

 

overflow data)

RATE 1/SEC

Number of monitored interactions per second (without overflow

 

data)

BUCKET

Corresponds to the bucket limits in seconds in which monitored data

 

is arranged in accordance with duration. The last line of the columns

 

(>) contains the overflow data. Data displayed there is not is not

 

used for computing AVG SEC, NR. INTER and RATE 1/SEC.

COUNT

Corresponds to the number of interactive operations in the

 

individual buckets

The SM2 administrators can modify the bucket limits and the number of buckets by means of the SET- and MODIFY-RESPONSETIME-PARAMETER statements if the default options are not suitable. If no interactions were recorded in the last monitoring cycle, the message NOTE: SOME INTERACTIONS MISSED:<number> is displayed in the bottom line of each of the RESPONSE TIME screens. This may be the case, for example, if the number of active connections is greater than that defined in the CONNECTION-NUMBER parameter of the SET- or MODIFY-RESPONSETIME-PARAMETER statement.

INPUT-LEN

The average lengths in bytes of the input or

OUTPUT-LEN

output messages

 