NPS0040

 

Messages

 

 

NPS0040

SM2 STXIT: CLASS=(&00), CODE=(&01), LOCATION=(&02). PROGRAM RUN ABORTED

 

(B) Routing code: R Weight: 99

 

Meaning

 

 

An error has occurred in the unprivileged program part of SM2.

 

CLASS:

event class.

 

CODE:

error weight.

 

LOCATION: program counter of the location at which the error occurred.

 

For further information on the STXIT routine see the ’Executive Macros’ manual.

NPS0041

TOO MUCH USERS WANT TO MONITOR THE SAME FILE

 

Meaning

 

 

Maximal 64 users can monitor the same file at the same time.

NPS0044

USER NOT AUTHORIZED TO MONITOR TASK. COMMAND REJECTED

 

(B) Routing code: R Weight: 99

 

Meaning

 

 

The SM2 administrator has not permitted task monitoring. As a result, monitoring of the

 

user task either cannot be started or can no longer be stopped by the user.

 

If the user himself started the monitoring of his task by means of a

 

/START-TASK-MEASUREMENT command, monitoring has already been terminated by the

 

SM2 administrator.

NPS0045

TASK ALREADY BEING MONITORED BY SM2

 

(B) Routing code: R Weight: 50

 

Meaning

 

 

Monitoring of the task has already been started either by the user via

 

the /START-TASK-MEASUREMENT command or by the SM2 administrator.

NPS0046

TASK MONITORING NOT INITIATED BY ’/START-TASK-MEASUREMENT’. COMMAND REJECTED

 

(B) Routing code: R Weight: 99

 

Meaning

 

 

Task monitoring cannot be terminated, either because it was not started by the

 

/START-TASK-MEASUREMENT command or because it has already been terminated in

 

the meantime (e.g. due to withdrawal of permission to monitor the task or to SM2

 

shutdown).

 

NPS0047

SPECIFIED TASK DOES NOT EXIST

 

Meaning

 

 

A TSN was specified for which no task exists.

 

 

 

 

 

 

374

U3585-J-Z125-8-76

Page 374
Image 374