Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Periodic Task report, Tu+Tpr

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 283
Image 283

SM2 reports

PERIODIC TASK report

Monitoring information

The first header line shows the report name and the sort criterion used (CPU, IO, UPG or S-U for service units).

The second header line displays the following global system values:

TU+TPR

Percentage of the (TU+TPR+SIH+IDLE) time accounted for by the

 

(TU+TPR) time

SIH

Percentage of the (TU+TPR+SIH+IDLE) time accounted for by the

 

SIH time

IDLE

Percentage of the (TU+TPR+SIH+IDLE) time accounted for by the

 

IDLE time

IO(/S)

Total number of I/Os per second in the last cycle

(2 LM’S)

Number of logical machines which were active

The PERIODIC TASK report contains data for the tasks selected with the SELECT- PERIODIC-TASK-PARAMETER statement (see page 177). By default, the data of all tasks is output.

D016ZE04 SM2 PERIODIC TASK (S-U)

 

CYCLE: 120 S

 

 

 

99-03-24

14:30:00

 

TU

+ TPR= 45.2

%

SIH= 10.5 %

IDLE= 44.3 %

 

IO(/S)=

402.8

( 2 LM'S)

TSN

USERID

TYP

SERV-RATECPU-TIME

IO(/S)

UPG

PAG READ

 

-----+----------

+

-----

+

---------

+

--------

+

--------

+

--------

+

---------

+---------

 

 

 

 

 

 

 

 

9PF9

CCC

DIA

7089.3

6.6%

0.1

14457

0.0

 

9XJM

LKLK

DIA

5637.3

6.3%

7.5

5423

0.0

 

9XI6

LKLK

DIA

2929.8

3.9%

0.3

743

0.0

 

9RBI

DRR

DIA

2677.7

3.0%

18.5

2433

0.0

 

9XIW

LKLK

DIA

2575.5

3.3%

2.3

743

0.0

 

9XJA

SD222222

DIA

1527.7

1.6%

8.9

506

0.0

 

BCAM

SYS

1356.2

0.2%

191.7

818

0.0

 

9UYY

GRR

DIA

1108.8

1.4%

7.3

347

0.0

 

9XJN

SD222222

DIA

1062.2

1.1%

8.9

506

0.0

 

9XIF

SD222222

DIA

916.5

0.9%

8.9

506

0.0

 

SM2G

SYS

880.7

1.2%

0.1

539

0.0

 

9XII

SD222222

DIA

808.4

0.8%

8.9

496

0.0

 

9UMB

WBB

DIA

750.5

0.9%

0.7

1686

0.0

 

9XIZ

SD222222

DIA

748.7

0.7%

8.9

506

0.0

 

9XJS

SD222222

DIA

734.1

0.7%

9.8

515

0.0

 

9WJ7

TSOS

BAT

724.0

0.0%

7.0

207

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U3585-J-Z125-8-76

283

Page 283
Image 283
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Periodic Task report, Tu+Tpr