Messages

NPC0061

NPC0061 ERROR IN COSMOS-WRITETASK

Meaning

The buffer task for the file with linkname ’(&00)’ returns an error.

You can determine the detailed error cause using the trace entries of the //SHOW-SM2- STATUS function.

NPC0062 MONITORING PROGRAM COSMOS ALREADY INITIALIZE. STATEMENT REJECTED

Meaning

An attempt was made to initialize the monitoring program COSMOS that has already been initialize or start.

NPC0063 ERROR DURING START OF UTM MEASUREMENT. MEASUREMENT PROGRAM COSMOS NOT STARTED.

Meaning

Event UTM cannot be opened, because the subsystem UTM is not created.

Statement //INIT-COSMOS or //START-MEASURMENT-PROGRAM COSMOS rejected.

Response

Create subsystem UTM first and then start the COSMOS measurement.

NPC0064 ERROR DURING PROCESSING OF COSMOS MEASUREMENT FILE: ’(&00)’

Meaning

You can determine the detailed error cause using the trace entries of the //SHOW-SM2- STATUS function.

NPC0065 INVALID FCBTYPE OF COSMOS MEASUREMENTFILE

Meaning

The indicated file exists already and does not have the FCBTYP PAM.

Response

Create a new file or access a file with correct FCBTYP PAM.

NPC0066 DMS-ERROR IN COSMOS-MEASUREMENTFILE ’(&01)’. DMS-CODE ’(&00)’. /HELP-MSG DMS(&00).

Meaning

For more detailed information about the DMS error code enter /HELP-MSG or see the BS2000 manual ’System messages’.

NPC0067 ERROR DURING MACROPROCESSING ’DCAMPNSM’.

U3585-J-Z125-8-76

367

Page 367
Image 367
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual NPC0061