Siemens U3585-J-Z125-8-76 1 manual Modify-Measurement-Periods, Modify SM2 monitoring cycle

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 93
Image 93

Statements for SM2 administrators

MODIFY-MEASUREMENT-PERIODS

MODIFY-MEASUREMENT-PERIODS

Modify SM2 monitoring cycle

Function

This statement is used to modify the SM2 time periods which control the cyclical acquisition of SM2 monitored data.

Format

MODIFY-MEASUREMENT-PERIODS

OFFLINE-PERIOD = *UNCHANGED / <integer 10..3600> ,ONLINE-PERIOD = *UNCHANGED / *SAME-AS-OFFLINE / <integer 10..3600> ,SAMPLING-PERIOD = *UNCHANGED / <integer 200..10000>

Operands

OFFLINE-PERIOD =

Specifies the SM2 monitoring cycle during which monitored data is collected and written to a file.

OFFLINE-PERIOD = *UNCHANGED

The monitoring cycle defined here remains unchanged. At the time the program started this value was defined as 150 seconds.

OFFLINE-PERIOD = <integer 10..3600>

Defines the SM2 monitoring cycle in seconds.

ONLINE-PERIOD =

Specifies the SM2 monitoring cycle during which the monitored data is collected for screen output and then displayed. The cycle of the background monitoring operations (namely gathering and writing the monitored data to the SM2 output file) is not changed.

ONLINE-PERIOD = *UNCHANGED

The online cycle remains unchanged. At program start time, this value is set to *SAME-AS- OFFLINE, i.e. no separate online cycle is defined.

U3585-J-Z125-8-76

93

Page 93
Image 93
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Modify-Measurement-Periods, Modify SM2 monitoring cycle