SM2 reports

DISK FILE report

 

Monitoring information

READ

Number of read operations per second

WRITE

Number of write operations per second

FILENAME

Name of the monitored file.

 

The first row always contains the value *OVERRUNS. This entry

 

includes all input/output operations that could not be assigned to a

 

file entry because the internal SM2 table was full during the

 

monitoring cycle. It is generally set to zero or to a low value.

 

In the FILENAME column, not all names are in the format:

 

<catid>:<$userid>.<filename>. In the case of special disk accesses

 

(e.g. by DAB), this format is not applied.

MN

Mnemonic device name of the monitored disk device

VSN

VSN of the monitored disk device

 

 

 

 

U3585-J-Z125-8-76

249

Page 249
Image 249