Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual Connection-specific parameters

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 48
Image 48

RESPONSETIME

SM2 monitoring programs

The message "NOTE: CONNECTION NUMBER TOO LOW" will be issued in the SM2 output report. Each of the RESPONSETIME screens (see description of the RESPONSETIME report) will show the same message. The message is output only if no interactions were recorded during the monitoring cycle in question.

An indication to this effect will be given in the SM2 response record at the end of this monitoring cycle.

With SM2R1, the message SOME INTERACTIONS MISSED will be issued at the end of the analysis. This message is output only if no interactions were recorded during the analysis period in question.

The BUCKET parameters consists of a list of the maximum response, think, transaction and wait times, arranged in order of magnitude. The ranges defined in the specified lists apply to all connection sets specified in the ADD-CONNECTION-SET statement.

<integer 1 .. 99999> is an integer which defines the limit value. The number of limit values in this list implicitly determines the number of ranges. This may vary from list to list, but five limit values is the maximum. The last value in the list of ranges specifies the overflow limit. All monitored variables that exceed this limit value are included under the last value, but are not included in the calculation of mean values given in the RESPONSETIME report.

Connection-specific parameters

The SM2 administrator can monitor the response time both globally, i.e. for all possible connections, and for specific individual connections, connection groups, or connection sets.

A connection is uniquely defined in the local the host by specifying the following objects:

the name of an application

the name of a partner

the host name of the partner

the type of connection

A connection group is understood as number of connections which are defined by speci- fying the objects listed above. The objects may be specified using a fully qualified name (name), a partially qualified name (name*), or an unqualified name (*ALL). For example, ($DIALOG,*ALL,*ALL) defines a connection group which includes the $DIALOG appli- cation.

A connection set is understood as a combination of connection groups. It is defined by specifying a list of up to five connection groups.

For example, (($DIALOG,*ALL,*ALL),(UTM1,*ALL,*ALL)) defines a connection set which combines two connection groups with the $DIALOG and UTM1 applications.

48

U3585-J-Z125-8-76

Page 48
Image 48
Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual Connection-specific parameters