SM2 information screens

 

 

STATUS TABLE

REASON

 

Reason for the trace entry. In many cases (with TYPE=S-ER) this is

 

 

the name of the system function which reported an error.

CREATE:

 

Creation of task

TERM:

 

Termination of task

Subsystem-STA:

Start of subsystem use

Subsystem-STO:

End of subsystem use

Subsystem-NLD:

Subsystem not loaded

TYPE

 

 

 

I-ER:

Internal error

(internal error during execution of SM2)

S-ER:

System error

(error calling a BS2000 system function)

TASK:

Task event

(start/end/crash of an SM2 task)

SS:

Subsystem event

(start/end of subsystem use by SM2)

MODUL

 

Abbreviated name of the SM2 module writing the trace entry

 

 

(without "NPS", "NPFS")

ID

 

Identifies the location at which the error occurred. In many cases

 

 

this is the offset within the module. If the error is unique within the

 

 

module, this field contains no entry.

CODE

 

Return code of the system function called (for TYPE=S-ER) or

 

 

additional information (for TYPE=I-ER) or zero

Note

The trace entries (particularly those with TYPE=I-ER,S-ER) are only relevant for SM2.

U3585-J-Z125-8-76

335

Page 335
Image 335