Statements for SM2 administrators

MODIFY-RESPONSETIME-PARAMETER

MODIFY-RESPONSETIME-PARAMETER

Modify parameters for RESPONSETIME monitoring

Function

This statement is used to modify the RESPONSETIME monitoring program definition.

Format

MODIFY-RESPONSETIME-PARAMETER

SCOPE = *UNCHANGED / list-poss(2): *BUCKET / *CATEGORY ,DEFINITION = *UNCHANGED / *1 / *2 ,CONNECTION-NUMBER = *UNCHANGED / <integer 1..8187>

,RESPONSETIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>

,THINKTIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>

,TRANSACTTIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>

,WAITTIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>

Operands

SCOPE =

Defines whether recording of the response time data is to be bucket-specific or category- specific.

SCOPE = *UNCHANGED

The scope defined by this time will not be changed.

SCOPE = *BUCKET

The response time data is to be recorded based on buckets.

SCOPE = *CATEGORY

The response time data is to be recorded based on categories.

U3585-J-Z125-8-76

95

Page 95
Image 95
Siemens U3585-J-Z125-8-76 1 manual Modify-Responsetime-Parameter, Modify parameters for Responsetime monitoring