Activating user task monitoring

SM2 operation

Formats

START-TASK-MEASUREMENT

TSN = *OWN / <alphanum-name 1..4> ,FILE = *STD / *BY-LINK-NAME

,PCOUNTER-INTERVAL = *NONE / <integer 1..10000> ,SVC-STATISTICS = *OFF / *ON

,LOAD-INFO = *STD / *DETAILED

STOP-TASK-MEASUREMENT

TSN = *OWN / <alphanum-name 1..4>

Operands

TSN =

Specifies the task to be monitored or for which monitoring is to be terminated.

TSN = *OWN

The task invoking the command will be monitored or monitoring of that task will be termi- nated.

TSN = <alphanum-name 1..4>

The task with the TSN specified is monitored or monitoring of that task is terminated. Only users who have been assigned the system privilege SW-MONITOR-ADMINISTRATION can start or terminate monitoring of any tasks. All other users can only monitor their own tasks.

Restriction: The task SM2U, which processes the user-specific SM2 output files, cannot be monitored.

FILE =

Specifies the user-specific SM2 output file.

FILE = *STD

The user-specific SM2 output file contains the file attributes which are defined in the following table.

FILE = *BY-LINK-NAME

The user defines the file name and further file attributes using the corresponding BS2000 commands. The file is assigned via the link name. The link name for the user-specific SM2 output file is PALINK.

190

U3585-J-Z125-8-76

Page 190
Image 190