Statements for nonprivileged users

SM2 operation

In controlled mode, the individual reports are output at the request of the user, i.e. the user can control SM2 report output or enter another statement.

The following scroll commands are available for controlling the output of SM2 reports which may comprise one or more screens:

1.++ selects the first screen of the first report of the next monitoring cycle.

2.- - selects the first screen of the first report of the current monitoring cycle.

3.+R selects the first screen of the next report.

If the current screen is the last for this monitoring cycle, the first screen of the first report of the next monitoring cycle is displayed.

4.–Rselects the first screen of the preceding report.

If the current screen is the first for this monitoring cycle, the current screen is displayed again.

5.+ selects the next sequential screen of the current report.

If the current screen is the last of the current report, the first screen of the next report is displayed. The DUE or DÜ1 key can also be pressed instead of the + key.

6.selects the preceding screen of the current report. If the current screen is the first of this report, the first screen of the preceding report is displayed.

7.> selects the overflow screen for the current report. Overflow reports can exist for DAB, PCA or UTM reports if it is not possible for all the monitored objects to fit on the same screen.

If there is no overflow screen, > has the same effect as +.

8.< selects the previous overflow screen.

If there is no overflow screen, < has the same effect as -.

9.<< selects the first screen of a report with overflow screens. If there is no overflow screen, << has the same effect as -.

10.+N selects the first report of the next host.

If the current screen is the last one of this monitoring cycle, the first screen of the first report from the next monitoring cycle is displayed.

In this case, the reports with network-specific data are displayed first, provided such reports were selected.

11.-Nselects the first report of the preceding host.

If the current report is the first one of the first host, the first report with network-specific data is displayed, provided such a report was selected.

This method is useful for checking that suitable output and control statements have been entered for a specific task or when a specific report is to be displayed for extended investi- gation at the terminal.