SM2 reports

SYMMETRIX CONTROLLER report

SYMMETRIX CONTROLLER report

This report provides an overview of the use of caches in the individual emulated 3860 controllers of a SYMMETRIX subsystem.

Report output

The REPORT SYMMETRIX statement is used to request the output of the SYMMETRIX CONTROLLER report. The report can only be output if the SM2 administrator has activated the monitoring process using the statement START-MEASUREMENT-PROGRAM TYPE=*PFA.

Overflow screens may be requested for this report.

The monitored data output is sorted under the categories READ and WRITE.

 

 

017ZE03

SM2 SYMMETRIX CONTROLLER CYCLE:

60 S

 

 

99-03-24

11:11:02

 

 

 

 

 

CONTROLLER

SIZE

READ

RD HIT

WRITE

WR HIT TOT HIT

 

 

 

 

 

MN

(1/S)

(%)

(1/S)

(%)

(%)

 

 

 

 

 

 

 

 

 

 

+

-------------

+

----------+

---------

+-------

+

---------

+-------

+

-------+

 

 

 

 

 

 

 

 

 

S6 /S7

1628 MB

420.3

100.0

229.6

100.0

100.0

 

 

 

 

 

+

-------------

+

----------+

---------

+-------

+

---------

+-------

+

-------+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

CONTROLLER MN

Mnemonic name of an emulated 3860 controller.

 

In all SM2 output, two controller mnemonics are always output

 

(separated by a slash) for an emulated 3860 controller. The

 

following two variants are provided:

 

alphanum-name 2..2

 

x-text 4..4

SIZE

Size of the usable cache in the SYMMETRIX subsystem

READ

Number of read operations per emulated 3860 controller and per

 

second

RD HIT

Percentage of read operations completed by the cache in relation to

 

the total number of read operations

WRITE

Number of write operations per emulated 3860 controller and per

 

second

U3585-J-Z125-8-76

303

Page 303
Image 303
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Symmetrix Controller report, Controller MN