Statements for SM2 administrators

MODIFY-COSMOS-PARAMETER

EVENT-SELECTION =

Specifies the events to be recorded. Their recording is linked to specific conditions.

EVENT-SELECTION = *UNCHANGED

The existing values for EVENT-SELECTION are not changed.

EVENT-SELECTION = *ALL-BY-ADD-COSMOS-EVENT

All open events are recorded.

EVENT-SELECTION = *SPECIFIED(...)

Only those events that satisfy the specified conditions are recorded.

EIA-INTERRUPT-CLASS =

Controls the recording of EIA events on the basis of their interrupt class (IC).

EIA-INTERRUPT-CLASS = *UNCHANGED

The currently specified ICs are not changed.

EIA-INTERRUPT-CLASS = *ANY

The recording of EIA events is independent of their IC.

EIA-INTERRUPT-CLASS = list-poss(5): *SVC / *PROGRAM / *MACHINE-CHECK / *IO / *EXTERNAL

Only those EIA events with the specified IC are recorded.

EIA-SVC-NUMBER =

Controls the recording of EIA events on the basis of their SVC.

EIA-SVC-NUMBER = *UNCHANGED

The currently specified SVCs are not changed.

EIA-SVC-NUMBER = *ANY

The recording of EIA events is independent of their SVC.

EIA-SVC-NUMBER = list-poss(8): <integer 1..255>

Only those EIA events with the specified SVC(s) are recorded.

IO-DEVICE =

Controls the recording of SDV, CHTM, IONQ and PMIO events on the basis of their mnemonic device name.

IO-DEVICE = *UNCHANGED

The currently specified mnemonic device names are not changed.

IO-DEVICE = *ANY

The recording of SDV, CHTM, IONQ and PMIO events is independent of their mnemonic device name.

IO-DEVICE = list-poss(8): <alphanum-name 2..4>

Only those SDV, CHTM, IONQ and PMIO events with the specified mnemonic device names are recorded.

U3585-J-Z125-8-76

89

Page 89
Image 89
Siemens U3585-J-Z125-8-76 1 Event-Selection = *Unchanged, Event-Selection = *All-By-Add-Cosmos-Event, Eia-Svc-Number =