SET-SERVICETIME-PARAMETER

Statements for SM2 administrators

SET-SERVICETIME-PARAMETER

Define SERVICETIME monitoring parameters

Function

This statement is used to define the devices for the SERVICETIME monitoring program.

Format

SET-SERVICETIME-PARAMETER

DEVICES = list-poss(256): <alphanum-name 2..4 with-wild>

Operands

DEVICES = list-poss(256): <alphanum-name 2..4 with-wild>

Specifies the mnemonic device names of the devices to be monitored. A check is carried out to establish whether these devices are defined in the configuration. An asterisk (*) is also permitted as the last character in a wildcard specification.

Note

Up to 256 devices are monitored. If partial qualification means that more than 256 devices are defined, these are selected in the following order of priority:

devices whose mnemonic device names have been specified in their entirety

devices whose mnemonic device names have been specified in partially qualified form

the sequence in the PDT (Physical Device Table)

130

U3585-J-Z125-8-76

Page 130
Image 130
Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual Set-Servicetime-Parameter, Define Servicetime monitoring parameters