NPS0515

NPS0515 SM2 SUBSYSTEM NOT AVAILABLE

(B) Routing code: R Weight: 99

Meaning

A non-privileged user has tried to start SM2 before the system administrator or a SM2 administrator had started the subsystem SM2 or subsystem SM2 was terminated during connection of user.

NPS0516 REQUIRED MODULES COULD NOT BE LOADED

(B) Routing code: R Weight: 99

Meaning

Certain monitoring program modules could not be loaded.

The return code of the loader function can be obtained by the SM2 administrator using the trace entries of the //SHOW-SM2-STATUS statement.

NPS0517 VERSION OF SM2 TU PART NOT SUPPORTED BY THE VERSION OF SM2 MODULE LIBARY. SM2 TERMINATES ABNORMALLY.

Meaning

It was tried to start a newer SM2 TU part with an older version of SM2 module library, which doesn’t support the version of SM2 TU part.

Response

Check the version number, if necessary unload subsystem SM2 and start it new.

NPS0518 CONFIGURATION RECORD COULD NOT BE WRITTEN

(B) Routing code: R Weight: 99

Meaning

This message is for diagnostic purposes only.

The configuration record could not be written either because certain resources were missing or because of a system error.

NPS0520 ONLY ’RECORD-FORMAT=VARIABLE’ PERMITTED FOR SM2 LOGGING FILE. STATEMENT REJECTED

Meaning

The value of the RECORD-FORMAT operand in the /SET-FILE-LINK command for a non-standard SM2 logging file is invalid.