NPC0068

Messages

NPC0068 FILE WITH LINKNAME ’COSFIL’ NOT FOUND.

Meaning

Possible reasons:

-The COSMOS measurement file assigned by LINK=COSFIL is not in the COSMOS parameter list.

-The COSMOS measurement file assigned by LINK=COSFIL does not exist.

Response

Enter the statement //SET-COSMOS-PARAMETER with the COSMOS measurement file assigned by LINK=COSFIL as parameter or create a COSMOS measurement file with

LINK=COSFIL.

NPC0069 ERROR DURING RDTFT-MACROPROCESSING.

NPC0070 SUBSYSTEM COSMOS NOT FOUND.

NPC0071 TO MANY MEASUREMENT FILES SPECIFIED.

Meaning

More than one measurement file for OUTPUT=*WRAP-AROUND(...) was specified.

Response

Enter the statement //SET-COSMOS-PARAMETER with only one measurement file for

WRAP-AROUND.

NPC0072 WRONG MEASUREMENT FILE SPECIFIED

Meaning

For VM2000- and COSMOS-Events the same measurement file was specified.

Response

Correct the statement and try again.

NPC0073 MEASUREMENT FILE FOR VM2000-EVENTS NOT SPECIFIED

Meaning

Measurement file for VM2000-Events was not specified in statement //SET-/MODIFY-COSMOS-PARAMETER.

Response

Correct statement and try again or close the VM2000-Events.

368

U3585-J-Z125-8-76

Page 368
Image 368
Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual NPC0068 Messages, Link=Cosfil, Wrap-Around