Siemens U3585-J-Z125-8-76 1 Set-Responsetime-Parameter, Define Responsetime monitoring parameters

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 127
Image 127

Statements for SM2 administrators

SET-RESPONSETIME-PARAMETER

SET-RESPONSETIME-PARAMETER

Define RESPONSETIME monitoring parameters

Function

This statement is used to define the monitoring parameters for the RESPONSETIME monitoring program.

Format

SET-RESPONSETIME-PARAMETER

SCOPE = *BUCKET / list-poss(2): *BUCKET / *CATEGORY

,DEFINITION = *1 / *2

,CONNECTION-NUMBER = *1024 / <integer 1..8187>

,RESPONSETIME-BUCKETS = *STD-LIMITS / list-poss(5): <integer 1..99999>

,THINKTIME-BUCKETS = *STD-LIMITS / list-poss(5): <integer 1..99999>

,TRANSACTTIME-BUCKETS = *STD-LIMITS / list-poss(5): <integer 1..99999>

,WAITTIME-BUCKETS = *STD-LIMITS / list-poss(5): <integer 1..99999>

Operands

SCOPE =

Defines whether the response time data is to be recorded by bucket or by category.

SCOPE = *BUCKET

The response time data is to be recorded by bucket.

SCOPE = *CATEGORY

The response time data is to be recorded by category.