SM2 reports

UTM APPLICATION report

UTM APPLICATION report

This report provides detailed information on a UTM application.

Report output

The UTM APPLICATION report is output only at the explicit request of the SM2 user with the help of the SELECT-UTM-APPLICATION statement (see page 182). This statement is used to output a UTM report together with a UTM APPLICATION report for the selected applications. The UTM APPLICATION report supplies detailed information on the UTM applications.

It is possible to output data on up to 16 applications.

The report can only be output if the SM2 administrator has activated the monitoring process using the statement START-MEASUREMENT-PROGRAM TYPE=*UTM.

Overflow screens may be requested for this report.

D016ZE04 SM2 UTM APPLICATION

CYCLE:

60

S

99-04-11

15:08:00

 

 

 

 

 

 

 

 

APPL: F2POOL

JOBN: JOBUTM01

UTM-VERS: V03.3A10 MODE: UTM-F

# DB‘S: 2

 

 

 

 

 

 

 

 

+--------------------

+

--------

+

 

 

+-------------------------

+

--------

+--------

+

# DIAL STEPS

(1/S)

0.0

 

 

MEAN VALUE FOR DIALOG

ASYNCH

# DIAL TA‘S

(1/S)

0.0

 

 

+-------------------------

+

--------

+--------

+

# ASYN TA‘S

(1/S)

0.0

 

 

TOTAL TIME

(S/RQ)

0.1

0.0

# ASYN CONV

(1/S)

0.0

 

 

TOT TIME WITH DB (S/RQ)

0.0

0.0

+--------------------

+

--------

+

 

 

STEPS WITH DB

(1/S)

0.0

0.0

# TASKS

 

3

 

 

TIME IN DB

(S/RQ)

0.0

0.0

# MAX ASYN TASKS

2

 

 

# DB CALLS

(1/RQ)

0.0

0.0

# CONNECTED USERS

1

 

 

CPU TIME IN DB

(MS/RQ)

0.0

0.0

# WAITING PRINTS

1

 

 

# IO IN DB

(1/RQ)

0.0

0.0

# WAITING ATACS

0

 

 

TOT TIME WITH DDP (S/RQ)

0.0

0.0

# WAITING DPUTS

14

 

 

STEPS WITH DDP

(1/S)

0.0

0.0

# DIALOG CURR CONV

1

 

 

TIME IN DDP

(S/RQ)

0.0

0.0

# ASYN CURR CONV

0

 

 

CPU TIME

 

(MS/RQ)

22.5

0.0

CACHE HIT RATE

 

(%)

86

 

 

# IO

 

(1/RQ)

5.5

0.0

FREE PAGE POOL

 

(%)

4

 

 

+-------------------------

+

--------

+--------

+

BOURSE WAIT T

(MS)

0

 

 

 

 

 

 

 

 

 

+--------------------

+

--------

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

APPL

Name of the UTM application

JOBN

BS2000 job name for the first task started for the UTM application

UTM-VERS

UTM version

MODE

UTM-S or UTM-F mode

U3585-J-Z125-8-76