Table 7-1. Main Screen Actions

 

 

Action

Function

 

 

Save

Saves changes to settings.

Undo

Returns all settings to the last saved state.

Refresh

Updates certain time-related information fields that are not automatically

 

updated (i.e., test status).

 

 

Copy

Copies the contents of the current column to the next column. Useful if you

 

change a lot of entries in one column and wants to repeat those changes in

 

subsequent columns.

 

 

Test

Access is given to the test screen

taBs

Index into the signaling conversion screen.

Main

Returns to the System Main Screen. If you make changes to settings and do

 

not save them, you will be prompted to save or lose changes.

 

 

Table 7-2, “Main Screen Option Settings and Defaults,” on page 7-7summarizes the configuration settings for the E&M port, along with the available and factory-default option settings. The parameters and settings are also described in the following paragraphs.

Table 7-2. Main Screen Option Settings and Defaults

Parameter

 

User Options

Notes

Default

 

 

 

 

 

STATE

stdby

actv

 

stdby

WAN/SRV

none

wan-1 wan-2 wan-3 wan-4 owan-1 owan-2

 

none

 

owan-3 owan-4

 

 

 

 

 

 

TS

01-24 or 01-31

 

01

MODE

to e&m I e&m II e&m IV e&m V

 

to

Rx TLP

-16.3 dB to +7.5 dB

 

0

Tx TLP

-16.3 dB to +7.5 dB

1

0

CODING

u-law a-inv

 

u-law

LB

off

dgtl anlg

 

off

PATTRN

none

D-mW

 

none

SIG CONV

n/a off on

23

off

Notes:

1.The extended setting range for the IMACS-200 E&M port is from -16.3to +7.5 dB.

2.When a WAN or SRV port has not been selected, or when the mode it to, the default for Signal Conversion is n/a. When the mode has been selected to be e&m, then the default is off.

E&M Ports

7-7

Page 167