E&M Ports 7-7
Table 7-1. Main Screen Actions
Table 7-2, “Main Screen Option Settings and Defaults,” on page 7-7 summarizes the
configuration settings for the E&M port, along with the available and factory-default option
settings. The parameters and settings are also described in the following paragraphs.
Table 7-2. Main Screen Option Settings and Defaults
Notes:
1. The extended setting range for the IMACS-200 E&M port is from -16.3 to +7.5 dB.
2. When a WAN or SRV port has not been selected, or when the mode it to, the default
for Signal Conversion is n/a. When the mode has been selected to be e&m, then the
default is off.
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Updates certain time-related information fields that are not automatically
updated (i.e., test status).
Copy Copies the contents of the current column to the next column. Useful if you
change a lot of entries in one column and wants to repeat those changes in
subsequent columns.
Test Access is given to the test screen
taBs Index into the signaling conversion screen.
Main Returns to the System Main Screen. If you make changes to settings and do
not save them, you will be prompted to save or lose changes.
Parameter User Options Notes Default
STATE stdby actv stdby
WAN/SRV none wan-1 wan-2 wan-3 wan-4 owan-1 owan-2
owan-3 owan-4 none
TS 01-24 or 01-31 01
MODE to e&m I e&m II e&m IV e&m V to
Rx TLP -16.3 dB to +7.5 dB 0
Tx TLP -16.3 dB to +7.5 dB 1 0
CODING u-law a-inv u-law
LB off dgtl anlg off
PATTRN none D-mW none
SIG CONV n/a off on 23 off