Cross-Connecting WAN Time Slots System Configuration and Operation

WARNING!

When cross-connecting multiple independent data DS0 time slots (sequentially grouped time slots should work) for data. Super-rate [data type cross-connect] is multiple DS0s sequentially assigned between WAN aggregates in a cross-connect system. DO NOT attempt to save time by cross-connecting independent data time slots as one super-rate circuit (could cause data errors.) This limitation does not apply to voice time slots.

Figure 3-25.New Circuit Selection and ID Assignment

W/U

The first WAN Unit (W/U) column is the T1 link in which the pass-through connection begins (since these circuits are bi-directional, the concept of beginning or ending is used for illustrative purposes only). The options are all WAN ports and ports, and the identification uses the same convention (wan-1,wan-2, etc.) seen earlier. If a WAN port is not present in the W/U selected, an error message is generated.

3-34

System Operation

Page 76
Image 76
Zhone Technologies IMACS-200 manual New Circuit Selection and ID Assignment