3-2 System Operation
Model No.
Running Head
System Power-up System Configuration and Operation
3.3.1 System Boot
Following the application of power, proceed as follows:
1. Be sure your system and local terminal are both powered up.
2. Connect a VT100-compatible terminal to the SERIAL jack on the faceplate of the
IMACS-200 front panel. Use a cable with an RJ-45 modular plug on one end for this
connection.
3. Configure the terminal to operate at 9.6 kbps, 8 data bits, no parity, and 1 stop bit.
Should your SERIAL cable be connected prior to powering the IMACS-200, or should
power be removed and re-applied to the IMACS-200 during this process, the following
screen will appear:
Figure 3-1.Testing and Initialization Screen
4. Press the RETURN key. The Login Screen appears.
The system will display Figure 3-1 above. When testing and initializing is complete the screen
will go blank. Press the <Enter> key. The Syst em Login Screen wil l displ ay, as seen in Figure
3-2