A.3 Chassis Standards

A.3.1 Dimensions

Chassis Description

Model

Height

Width

Depth

Weight

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in

cm

in

cm

in

cm

lb.

kg

 

 

 

 

 

 

 

 

 

 

Steel Chassis , Dual-Powered,

IMACS-200

3.47

8.8

9.48

24.1

17.31

44.0

10.0

4.5

OHSU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.3.2 Chassis Power

 

Model

AC Power (50-60 Hz)

DC Power

Power

Chassis Description

Consumption

Number

 

 

 

 

 

 

 

 

 

 

 

110 VAC

220 VAC

-48 VDC

125 VDC

Watts

 

 

 

 

 

 

 

 

 

Steel Chassis , Dual-Powered,

IMACS-

115 VAC

175 VAC

-40 VDC

 

125 (typical)

OHSU.

200

104 to 135

to 264

to -60

 

500 W

 

 

VAC

VAC

VDC

 

(maximum)

 

 

 

 

 

 

 

A.3.3 Environment

A.3.3.1 Ambient Temperature and Humidity

Ambient temperature and humidity as per IEEE 1613 - 2003 Section 4.1.

Temperature o C / o F\

Humidity

Operate

Storage

Operate

 

 

 

-40oC to 70oC

-50oC to 85oC

55 to 95% relative

-40oF to 158oF

-58oFto 185oF

humidity, non

 

 

condensing

Rate of temperature change

30 o C/hr (54 o F/hr)

Ambient refers to conditions at a location 30 cm (11.81 inches) from the surface of the unit enclosue while in operation.

A.3.3.2 Airflow

The IMACS-200 includes two fans. The fans are temperature controlled to automatically turn on and off as needed.

A-2

System Standards and Specifications

Page 254
Image 254