System Testing and Diagnostics

User port Diagnostics

14.3.2 Voice Diagnostics

The software-initiated diagnostics supported are voice ports include the setting of both analog and digital loopbacks toward the network and the generation of Quiet Tone and a Digital MilliWatt signal on a port-by-port basis. The operator can also monitor and set the state of the analog leads of any FXS or E&M port. They can set and monitor the state of the ABCD signaling bits of the digitized voice signal. In cross-connect system, test functionality also includes the ability to generate test tones (300Hz, 1 kHz and 3 kHz) and transmit those toward the user side or the network side of the system. The table below shows detailed information on the diagnostic capabilities of the Voice ports.

 

4-wire E&M

2-wire FXS

 

 

 

On-port loopbacks

 

 

Analog Toward Network

Yes

Yes

Digital Toward Network

Yes

Yes

Signaling Manipulation

 

 

Set Status of Analog Interface Leads

Yes

Yes

Set Transmit ABCD Signaling Bits

Yes

Yes

Set Receive ABCD Signaling Bits

Yes*

Yes*

Monitor Status of Analog Interface

Yes

Yes

Leads

 

 

Monitor Status of Transmit ABCD

Yes

Yes

Signaling Bits

 

 

Monitor Status of Receive ABCD

Yes

Yes

Signaling Bits

 

 

Tone Generation

 

 

 

 

 

Tone Supported

 

 

300 Hz

Yes*

Yes*

1 kHz

Yes*

Yes*

3 kHz

Yes*

Yes*

Quiet Tone

Yes

Yes

Digital MilliWatt

Yes

Yes

Tone Direction

 

 

Toward User

Yes

Yes

Toward Network

Yes

Yes

Diagnostics

14-3

Page 247
Image 247
Zhone Technologies IMACS-200 manual Voice Diagnostics, System Testing and Diagnostics User port Diagnostics