Test Screen | SRU Ports |
CTS
The Clear To Send (CTS) option allows you to define whether the CTS control lead should be held on (high) or off (low). Selecting either on or off will override the selection made in the SRU port screen. The third option is norm (normal) which means that CTS will behave as described in Table
RLSD
The Receive Level Signal Detect (RLSD) option allows you to define whether the RLSD control lead should be held on (high) or off (low). The third option is norm (normal) which means that RLSD will behave as described in Table
SYNC
The Synchronization (SYNC) field tells you if the integrated BERT has achieved synchronization either with itself via a remote loopback or with the remote test equipment. Since this is an
BE
The Bit Error field shows the total number of bit errors logged. Since this is an
ES
The Errored Seconds field shows the total number of seconds in which any errors were detected. Since this is an
SES
The Severely Errored Seconds (SES) field shows the total number of seconds in which the bit error rate exceeded one bit per thousand (1 x
CSES
The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten consecutive Severely Errored Seconds. Once triggered, the CSES field will increment (by one) for each elapsed second until the system logs ten consecutive
Sub Rate Data Ports |