SRU Ports

Test Screen

 

 

 

 

 

Table 8-4. Test Screen Actions

 

 

 

 

 

 

 

 

 

 

 

Action

 

 

 

Function

 

 

 

 

 

 

 

 

 

Save

 

Saves changes to settings.

 

 

 

 

 

 

 

 

 

Undo

 

Returns all settings to the last saved state.

 

 

 

 

 

 

 

 

 

Refresh

 

Updates certain time-related information fields that are not automatically

 

 

 

 

updated (i.e., test status).

 

 

 

 

 

 

 

 

 

InsertErr

 

Allows you to manually insert a single error into the clear data signal.

 

 

 

 

 

 

 

 

Clear

 

Clears the Test Screen and resets all counters to zero.

 

 

 

 

 

 

 

 

 

Main

 

Returns to the SRU port Main Screen. If changes are made to settings and

 

 

 

 

not saved, you will be prompted to save or lose changes.

 

 

 

 

 

 

 

 

 

 

Table 8-5. Test Screen Option Settings and Defaults

 

 

 

 

 

 

 

 

Parameter

 

 

 

User Options

Default

 

 

 

 

 

BERT

off

mark

space 1:1 1:7 511 qrss 2047

off

 

 

 

 

 

DIR

net

user

 

net

 

 

 

 

 

CTS

norm

off

on

norm

 

 

 

 

 

RLSD

norm

off

on

norm

 

 

 

 

SYNC

information only–no user options

*****

 

 

 

 

 

BE

information only–no user options

*****

 

 

 

 

 

ES

information only–no user options

*****

 

 

 

 

 

SES

information only–no user options

*****

 

 

 

 

 

CSES

information only–no user options

*****

 

 

 

 

 

OSS

information only–no user options

*****

 

 

 

 

 

BER

information only–no user options

*****

 

 

 

 

 

ELAP

information only–no user options

*****

 

 

 

 

 

RTS

information only–no user options

*****

 

 

 

 

 

SR OSS

information only–no user options

*****

 

 

 

 

 

LB ST

information only–no user options

*****

 

 

 

 

 

 

 

 

 

BERT

Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) on the selected SRU port. The patterns that can be selected are off, mark (all ones), space (all zeros), 1:1 (alternating 10101010), 1:7 (10000000), 511 (511 test pattern), and 2047 (2047 test pattern).

DIR

The Direction (DIR) setting allows you to specify where the BERT test signal should be directed. The first option is net (network) which means that the test signal will be transmitted through the system toward the Wide Area Network (WAN). The user option means that the signal will be directed toward the attached DTE device over the RS-232 interface.

Sub Rate Data Ports

8-9

Page 185
Image 185
Zhone Technologies IMACS-200 manual SRU Ports Test Screen, Dir, Test Screen Actions Function