Alarms

System Configuration and Operation

3.7.2Alarm Filter Settings

You can set filters for each alarm so that the alarm reports occurrences in a number of different ways. Figure 3-11shows the Alarm Filters screen, which is accessed by pressing "f" (Filters command) on the Alarm Screen.

Figure 3-11.Alarm Filters Screen

The first column of the Alarm Filters Screen is the alarm abbreviation that appears when an alarm is generated. The second column is the associated full name of each alarm. Table 3-2describes each alarm appearing in the Alarm Filters Screen.

The third column contains the filters ignore, log, and report. Set the filter to ignore if you want the system to ignore the alarm. Or, set it to log if you want the system to show the alarm report on the screen and also log it into the Alarm History, as described later in this chapter.

Set the filter to report if you want the system to send (report) the alarm indication to a remote device. With this setting, the system will also display the alarm report on the screen and log it into the Alarm History.

The fourth column of the Alarm Filters Screen contains the filter modifiers info, minor, major, and crit. This column specifies a level of importance (information only, minor alarm, major alarm, or critical alarm) for each alarm. These settings are described later in this chapter.

The last column sets the alarm cutoff (ACO) to aco-offor aco-on. These settings are explained later in this chapter.

The filter in the third column takes precedence over its modifier. If, for instance, you have an alarm filter set to ignore, the setting of the modifier as info, minor, major, or crit will be ignored. Refer to system specifications section in this manual for alarms and their meanings.

3-16

System Operation

Page 58
Image 58
Zhone Technologies IMACS-200 manual Alarm Filter Settings, Alarm Filters Screen