7-12 E&M Ports
Model No.
Running Head
TEST
The Test parameter shows if the port is in test mode or not. Inactive ports and ports that are
assigned to inactive WANs will show a test status of n/a. The test status options for active
ports are off and on.
Tx ABCD
The Transmit ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being transmitted towards the network or set a specific ABCD pattern for testing the
transmit side of the circuit. The options fo r this field are mon (monitor) or set. Choosing set
will bring up a four digit field for users to input the ABCD pattern they want to transmit. Any
four-digit combination of ones and zeros is acc ep table for this setting.
Rx ABCD
The Receive ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being received from the network or set a specific ABCD pattern for testing the receive
side of the circuit. The options for this field are mon (monitor) or set. Choosing set will bring
up a four digit field for users to input the ABCD pattern they want to receive. Any four digit
combination of ones and zeros is acceptable.
E-lead
The E-lead setting allows the user to either monitor or set the state of the E-lead. T he optio ns
for this field are mon (monitor) or set. Choosing set will bring up the options on (whi ch raises
the E-lead), or off (which drops the E-lead.
Rx ABCD mon set mon
E-Lead mon mon
TO USER none D-mW none
TO NTWK none D-mW none
Tx ABCD Status information only; not editable n/a
Rx ABCD Status information only; not editable n/a
E-lead Status information only; not editable
M-lead Status information only; not editable
MODE Status information only; not editable n/a
TYPE Status information only; not editable n/a
STATUS Status information only; not editable n/a