Alarm port User Screens and Settings | Alarm ports |
| Table | |
Action |
| Function |
|
|
|
Save |
| Saves changes to settings. |
Undo |
| Returns all settings to the last saved state. |
Refresh |
| Updates certain |
|
| updated on screen (i.e., alarm data). |
|
|
|
Main |
| Returns to the System Main Screen. If changes are made to settings and |
|
| not saved, you will be prompted to save or lose changes. |
|
|
|
Table 11-2. Alarm Contacts Settings and Defaults
Parameter |
| User Options | Default |
|
|
|
|
SWITCH | stdby | actv | stdby |
ACT ON | minor | major any | minor |
SENSOR | stdby | actv | stdby |
TRIG ON | close | open | close |
SWITCH
The Switch setting indicates that the outbound alarm switch is actv (on) or stdby (off).
ACT ON
The Act On parameter defines the type of system alarm that will cause the switch to trigger. Program each alarm switch to trigger on minor (information and minor) alarms, major (major and critical) alarms, or any alarm message.
SENSOR
The Sensor setting indicates the inbound alarm sensor is actv (on) or stdby (off).
TRIG ON
The Trigger On parameter defines if the sensor should report an external alarm upon sensing the opening (open) or the closure (close) of the external contact to which it is connected.
Alarm Ports |