.System with Cross-Connect Option

System Testing and Diagnostics

14.4 .System with Cross-Connect Option

14.4.1 Circuit Diagnostics

In systems equipped with Cross-Connect CPUs, the cross-connect element adds another level of testing within the node and enhances the system’s diagnostic capabilities. The operator may also monitor and set the state of the Transmit and Receive ABCD signaling bits of a digitized voice circuit that is cross-connected between WANs. The table below shows detailed information on the diagnostic capabilities of the circuits.

 

Voice

Voice with

Single Data

Super-rate

 

without

DS0

Data

 

Signaling

 

Signaling

(64 Kbps)

(N x 64 Kbps)

 

 

 

 

 

 

 

Loopbacks

 

 

 

 

 

 

 

 

 

Local loopbacks

 

 

 

 

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

 

 

 

 

 

Bit Error Rate Tester (BERT)

 

 

 

 

 

 

 

 

 

Patterns Supported

 

 

 

 

All 1s

Yes

Yes

Yes

Yes

All 0s

Yes

Yes

Yes

Yes

1:1

Yes

Yes

Yes

Yes

1:7

Yes

Yes

Yes

Yes

M_OOS

Yes

Yes

Yes

Yes

BERT Direction

 

 

 

 

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

 

 

 

 

 

Tones Supported

 

 

 

 

300 Hz

Yes

Yes

Yes

Yes

1 kHz

Yes

Yes

Yes

Yes

3 kHz

Yes

Yes

Yes

Yes

Tone Direction

 

 

 

 

Toward WAN1

Yes

Yes

Yes

Yes

Toward WAN2

Yes

Yes

Yes

Yes

14-4