Rx ABCD

mon set

mon

TO USER

none D-mW

none

TO NTWK

none D-mW

none

 

 

 

Tx ABCD

Status information only; not editable

n/a

Rx ABCD

Status information only; not editable

n/a

MODE

Status information only; not editable

n/a

TYPE

Status information only; not editable

n/a

STATUS

Status information only; not editable

n/a

TEST

The Test parameter shows if the port is in test mode or not. Inactive ports and ports that are assigned to inactive WANs will show a test status of n/a. The test status options for active ports are off and on.

Tx ABCD

The Transmit ABCD setting allows the user to either monitor the status of the ABCD signaling bits being transmitted towards the network or set a specific ABCD pattern for testing the transmit side of the circuit. The options for this field are mon (monitor) or set. Choosing set will bring up a four digit field for users to input the ABCD pattern they want to transmit. Any four-digit combination of ones and zeros is acceptable for this setting.

Rx ABCD

The Receive ABCD setting allows the user to either monitor the status of the ABCD signaling bits being received from the network or set a specific ABCD pattern for testing the receive side of the circuit. The options for this field are mon (monitor) or set. Choosing set will bring up a four digit field for users to input the ABCD pattern they want to receive. Any four digit combination of ones and zeros is acceptable.

TO USER

In cross-connect systems only, the To User parameter allows you to break the circuit and send a test tone on the user side of the system. The options for this field are none, and D-mW. Choose none if you do not want to inject a tone toward the CPE. In this case, the PCM signal received from the network is still sent to the CPE in the normal manner.

6-8

FXS Ports

Page 156
Image 156