6-4 FXS Ports
Model No.
Running Head
TS
The TS setting identifies the time slot on the WAN link to which thi s port is assigne d. Values
range from 1 to 24 for T1 links, and 01 to 31 for E1 links. For a display of the available time
slots, refer to the cross-connect map for th e WAN link; see Chapter 4, System Configuration
and Operation in the System Reference Guide for information ab out viewing cross-connect
maps.
CAUTION!
Before activating this port, verify the behavior expected by both the station equipment and
remote central office equipment, and be sure the systems are properly configured.
MODE
The Mode setting should be determined by the type of equipment to which the user is
connecting the port. Currently the only allowable option uses two-wire balanced c onnections.
The fxs (Foreign Exchange Station) option allows users to connect the system to a two-way
(both inbound and outbound calls) PBX trunk or a key system trunk. The system requires a
ringing generator for this option.
The plar (private line automatic ringdown) option provides point-to-point unswitched
connections between two telephone sets. This configuration is usually not attached to an
exchange or switch; rather it provides a “hot line” between two locations. The IMACS-200
only supports d4-m2 version of plar, where the receiver generates ring cadence, offhook = 0
and onhook = f.

Rx TLP

The Receive Transmission Level Point (TLP) setting control s the amount of gai n or loss added
to the incoming signal after it is decoded to analog. T o increase t he signal level, set the Rx TLP
setting to a positive value (i.e., the larger the number , the more g ain is added). T o de crease the
signal level, set the Rx TLP setting to a negative value (i.e., the more negativ e the number , the
more the signal level is decreased). For example, an incoming signal at -5 dBm can be
increased to -3 dBm by setting Rx TLP to +2 dB. The Rx TLP range is -9.0 dB to +3.0 dB.

Tx TLP

The Transmit TLP setting controls the amount of gain or loss a dded to a voice signal f rom the
CPE before it is encoded to digital PCM. To increase the signal level, set the Tx TLP setting
to a negative value (i.e., the more negative th e number, the more gain is added). To decrease