A.4.2 FXS port Specifications

FXS ports IMACS-200-FXS

Number of Ports

IMACS-200-FXS

 

4 ports

 

Physical Interface

 

 

 

Connector

 

1 female 50-pin telco connector

 

 

 

Transmission Performance

 

 

Performance

 

Exceeds requirements of ITU-T Rec. G.713

 

 

 

 

Signaling Modes

 

 

 

Signaling Modes

 

Foreign Exchange Station (FXS) Loop Start and Private Line

 

 

Automatic Ringdown (PLAR)

 

 

 

 

Termination Impedance

 

 

 

IMACS-200-FXS

 

600 Ohms with 2.16 F

 

 

 

VF Transmission Characteristics

 

 

Nominal Transmit TLP

 

Defaults to +2.0 dB. Can be set from -6.5 dB to +9.0 dB

Nominal Receive TLP

 

Defaults to -2.0 dB. Can be set from -9.0 dB to +3.0 dB

PCM Encoding

 

Software selectable on a per port basis

 

Attenuation Versus Frequency Relative to 1 kHz with 0 dBm0 input

Frequency

Transmit (A to D)

Receive (D to A)

200 Hz

-0.25 to +3.0 dB

-0.25 to +2.0 dB

300 to 3000 Hz

-0.25 to +0.5 dB

-0.25 to +0.5 dB

3200 Hz

0.25 to +0.75 dB

-0.25 to +0.75 dB

3400 Hz

-0.25 to +1.5 dB

-0.25 to +1.5 dB

 

 

 

 

Return Loss (at 1 kHz)

 

>28 dB

 

Transhybrid Loss

 

34dB

 

Idle Channel Noise (rcv and xmt)

< -65 dBm0p Typ < -70 dBmop or < 20 dBrnc0

Interchannel Crosstalk

 

Typ < -75 dBm0 using 7 adjacent channels being disturbed with a signal

 

 

of 0.0 dBm0

Total Distortion including Quantization (Signal to Distortion Ratio) Input Frequencies 1004-1020 Hz

Input Level

Rcv or Xmt

Overall

-30 to 0 dBm0

>35 dB

>33 dB

-40 dBm0

>29 dB

>27 dB

-45 dBm0

>25dB

>22 dB

Absolute group delay

< 750 microseconds

Group Delay Distortion vs. frequency

within boundaries of ITU-T Rec. G.713 Figure 2

Longitudinal Balance

Nom > 46 dB

 

Typ > 50 dB

Variation of Gain with Input Level

within boundaries of ITU-T Rec. G.713 Figure 7

System Standards and Specifications

A-5

Page 257
Image 257
Zhone Technologies IMACS-200 manual FXS port Specifications, Automatic Ringdown Plar