8.1.5 Digital inputs - drive enable and DIN0 general purpose (X3)

 

Unit

All models

 

 

 

Type

 

Opto-isolated inputs

 

 

 

Input voltage

VDC

 

Nominal

 

24

Minimum

 

12

Maximum

 

30

 

 

 

Input current (maximum, per input)

mA

50

 

 

 

Sampling interval

ms

1

 

 

 

Minimum pulse width

µs

5

 

 

 

8.1.6 Digital inputs DIN1, DIN2 - high speed general purpose (X3)

 

Unit

All models

 

 

 

Type

 

Opto-isolated inputs

 

 

 

Input voltage

VDC

 

Nominal

 

24

Minimum

 

12

Maximum

 

30

 

 

 

Input current (maximum, per input)

mA

20

 

 

 

Maximum input frequency

MHz

1

 

 

 

Minimum pulse width

ns

250

 

 

 

8.1.7 Digital outputs DOUT0, DOUT1 - status and general purpose (X3)

 

Unit

All models

 

 

 

User supply (maximum)

V

28

 

 

 

Output current (max. continuous)

mA

100

 

 

 

Fuse

mA

 

Approximate trip current

200

Reset time

s

<20

 

 

 

Update interval

ms

1

 

 

 

8-4 Specifications