www.supportme.net

8-6 Specifications MN1942

8.1.12 CAN interface
Description Unit Value
Signal 2-wire,isolated
Channels 1
Protocol CANopen
Bitr ates Kbit/s
10,20, 50, 100, 125, 250, 500, 1000
8.1.13 Environmental
Allmodels Unit Allmodels
Operating temperature range* °C °F
Minimum
Maximum
Derate
+0
+45
Seesec tions
3.2.2to 3.2.5
+32
+113
Seesec tions
3.2.2to 3.2.5
Storagetemperature range* -40to+85 -40to+185
Humidity(maximum)* % 93
3A 6A 9A
Forcedair coolingf low
(vertical, from bottom to top)
m/s Nonerequir ed 12.5
Maximuminstallation altitude
(abovem.s .l.)
m
ft
1000
Derate1.1% / 100mover 1000m
3300
Derate1.1% / 330ftover 3300f t
Shock* 10G
Vibration* 1G,10-150Hz
IPrating IP20**
*Micr oFlex e100 complies with the following environmental test standards :
BSEN 60068-2-1:1993 low temperature operational 0°C.
BSEN 60068-2-2:1993 high temperature operational 45°C.
BSEN 60068-2-1:1993 low temperature storage/transportation -40°C.
BSEN 60068-2-2:1993 high temperature storage/transportation +85°C.
BS2011:part2.1 Cb: 1990: 45°C 93%R H humidity/high temperature operational.
DIN IEC 68-2-6/29
**MicroFlex e100 complies withEN61800-5-1:2003 part 5.2.2.5.3 (Impac t test), provided all front
panelconnec tors are inserted.