www.supportme.net

3.4.8 24V control circuit supply

A 24VDC supply must be provided to power the controlling electronics. This is useful for safety reasons where AC power needs to be removed from the power stage but the controlling electronics must remain powered to retain position and I/O information.

A separate fused 24V supply should be provided for the MicroFlex e100. If other devices are likely to be powered from the same 24V supply, a filter (Baldor catalog number FI0014A00) should be installed to isolate the MicroFlex e100 from the rest of the system. Alternatively, a ferrite sleeve may be attached to the supply cable near connector X2.

Location

Connector X2

 

 

 

Nominal input

24V

 

voltage

 

 

 

 

 

Range

20-30VDC

 

 

 

 

Input current

 

 

Maximum

1A continuous (4A typical power on surge, limited by NTC)

Typical

0.5A - 0.6A

(not powering feedback device)

 

0.6A - 0.8A

(powering feedback device)

 

 

 

Tightening torque for terminal block connections is 0.5-0.6Nm (4.4-5.3 lb-in).

Customer supplied

 

24V filter

Ferrite

24VDC

Fuse *

(optional)

sleeve**

+24V

 

 

 

 

 

GND

 

 

 

 

 

 

Use a twisted pair cable, with

 

 

 

ferrite sleeve attached close

 

 

 

to connector X2.

 

Incoming safety

 

 

 

earth/ground (PE)

 

 

 

 

STAR

 

 

 

POINT

 

* Recommended fuse: Bussman S504 20x5mm anti-surge 2A.

** Recommended ferrite sleeve: Fair-Rite part 0431164281 or similar.

Figure 6 - 24V control circuit supply connections

MN1942

Basic Installation 3-17

Page 31
Image 31