www.supportme.net

5-20 Input/ Output MN1942

5.6 Other I/O

5.6.1 Node ID selector switches

TheMic roFlex e100 has two selector switc hes which determine the unit’s
nodeID on EPL networks . Eachswitc h has 16 positions, allowing selection
of the hexadecimal values 0 - F. In combination, the two sw itches allow
nodeIDs of 0- 255 (hexadecimal FF) to beselected. The switch labelled‘HI’
sets the high nibble (half byte), and the switch labelled ‘LO’ sets the low
nibble.The following table lists all node ID s from 0 to 255 with the equivalent
HIand LO s witch settings:
NodeID HI LO NodeID HI LO Node ID HI LO NodeID HI LO
00 0 64 4 0 128 8 0 192 C 0
10 1 65 4 1 129 8 1 193 C 1
20 2 66 4 2 130 8 2 194 C 2
30 3 67 4 3 131 8 3 195 C 3
40 4 68 4 4 132 8 4 196 C 4
50 5 69 4 5 133 8 5 197 C 5
60 6 70 4 6 134 8 6 198 C 6
70 7 71 4 7 135 8 7 199 C 7
80 8 72 4 8 136 8 8 200 C 8
90 9 73 4 9 137 8 9 201 C 9
10 0 A 74 4 A 138 8 A 202 C A
11 0 B 75 4 B 139 8 B 203 C B
12 0 C 76 4 C 140 8 C 204 C C
13 0 D 77 4 D 141 8 D 205 C D
14 0 E 78 4 E 142 8 E 206 C E
15 0 F 79 4 F 143 8 F 207 C F
16 1 0 80 5 0 144 9 0 208 D 0
17 1 1 81 5 1 145 9 1 209 D 1
18 1 2 82 5 2 146 9 2 210 D 2
19 1 3 83 5 3 147 9 3 211 D 3
20 1 4 84 5 4 148 9 4 212 D 4
21 1 5 85 5 5 149 9 5 213 D 5
22 1 6 86 5 6 150 9 6 214 D 6
23 1 7 87 5 7 151 9 7 215 D 7
24 1 8 88 5 8 152 9 8 216 D 8
25 1 9 89 5 9 153 9 9 217 D 9
26 1 A 90 5 A 154 9 A 218 D A
27 1 B 91 5 B 155 9 B 219 D B
28 1 C 92 5 C 156 9 C 220 D C
29 1 D 93 5 D 157 9 D 221 D D
30 1 E 94 5 E 158 9 E 222 D E