www.supportme.net
5.2.6 General purpose output DOUT1
  | 
  | 
  | 
  | 
  | Location | Connector X3, pins 3 & 13  | |
3  | 
  | 
  | 
  | 13  | 
  | (Mating connector: Weidmüller Minimate B2L 3.5/20)  | |
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | Name | DOUT1  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | Description | General purpose   | |
  | 
  | 
  | 
  | 
  | 
  | Output current:  | 100mA maximum  | 
  | 
  | 
  | 
  | 
  | 
  | User supply:  | +28VDC maximum  | 
  | 
  | 
  | 
  | 
  | 
  | Update interval:  | 1ms  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
The optically isolated general purpose output is designed to source current from the user supply as shown in Figure 30. The PS2562L has a maximum power dissipation of 200mW at 25°C. The maximum saturated voltage across the outputs when active is 1.0VDC, so it can be used as a TTL compatible output.
The output includes a 
  | MicroFlex e100  | 
  | +3.3V  | 
220R  | 
  | 
  | Fuse  | 
  | 13  | 
  | 200mA  | 
[Error]  | 4n7  | 
  | TLP 127  | 
  | 4n7  | 
  | 3  | 
‘X3’
DOUT1+
DOUT1-
User supply V+
Load (Relay with diode shown)
User supply
GND
Figure 32 - DOUT1 output circuit
When the MicroFlex e100 is connected to Mint WorkBench, the active level of the output can be configured using the Digital I/O tool. Alternatively, the Mint keyword OUTPUTACTIVELEVEL can be used in the command window. See the Mint help file for details.
MN1942  | Input / Output   |