www.supportme.net
5.2.6 General purpose output DOUT1
|
|
|
|
| Location | Connector X3, pins 3 & 13 | |
3 |
|
|
| 13 |
| (Mating connector: Weidmüller Minimate B2L 3.5/20) | |
|
|
|
|
|
| ||
|
|
|
|
| Name | DOUT1 |
|
|
|
|
|
|
|
| |
|
|
|
|
| Description | General purpose | |
|
|
|
|
|
| Output current: | 100mA maximum |
|
|
|
|
|
| User supply: | +28VDC maximum |
|
|
|
|
|
| Update interval: | 1ms |
|
|
|
|
|
|
|
|
The optically isolated general purpose output is designed to source current from the user supply as shown in Figure 30. The PS2562L has a maximum power dissipation of 200mW at 25°C. The maximum saturated voltage across the outputs when active is 1.0VDC, so it can be used as a TTL compatible output.
The output includes a
| MicroFlex e100 |
| +3.3V |
220R |
|
| Fuse |
| 13 |
| 200mA |
[Error] | 4n7 |
| TLP 127 |
| 4n7 |
| 3 |
‘X3’
DOUT1+
DOUT1-
User supply V+
Load (Relay with diode shown)
User supply
GND
Figure 32 - DOUT1 output circuit
When the MicroFlex e100 is connected to Mint WorkBench, the active level of the output can be configured using the Digital I/O tool. Alternatively, the Mint keyword OUTPUTACTIVELEVEL can be used in the command window. See the Mint help file for details.
MN1942 | Input / Output |