3.2.4 Derating characteristic - 6A model
The following derating characteristics are for model MFE230A006.
Single-phase AC supply
| 6 |
|
|
|
|
|
) | 5 |
|
|
|
| 1.5m/s forced air |
rms |
|
|
|
|
|
|
(A | 4 |
|
|
|
|
|
current |
|
|
|
|
| |
|
|
|
|
| 1m/s forced air | |
3 |
|
|
|
|
| |
output |
|
|
|
|
| |
2 |
|
|
|
|
| |
Rated | 1 |
|
|
|
| Natural cooling |
| 0 |
|
|
|
|
|
| 30 | 35 | 40 | 45 | 50 | 55 |
Ambient temperature (°C)
Three-phase AC supply
| 6 |
|
|
|
|
|
) | 5 |
|
|
|
| 1.5m/s forced air |
rms |
|
|
|
| ||
|
|
|
|
|
| |
(A | 4 |
|
|
|
|
|
current |
|
|
|
|
| |
3 |
|
|
|
| 1m/s forced air | |
|
|
|
|
| ||
output |
|
|
|
|
| |
2 |
|
|
|
|
| |
Rated |
|
|
|
|
| |
1 |
|
|
|
| Natural cooling | |
| 0 |
|
|
|
|
|
| 30 | 35 | 40 | 45 | 50 | 55 |
Ambient temperature (°C)
Notes:
Load power factor = 0.75.
Overload limit for model MFE230A006 is 12A.