Page
Page
Contents
Feedback
Troubleshooting
Appendices
General Information
Safety Notice
Precautions
Product notice
000
General Information MN1942
MicroFlex e100 features
Installed at
Receiving and inspection
Identifying the catalog number
Catalog number MFE
Phase
Units and abbreviations
Introduction MN1942
Power sources
Introduction
Hardware requirements
These stages should be read and followed in sequence
Other information needed for installation
Tools and miscellaneous hardware
Mechanical installation and cooling requirements
Dimensions
Mounting and overall dimensions
Mounting and cooling the MicroFlex e100
Effects of mounting surface and proximity
Derating characteristic 3A model
Single-phase AC supply
Three-phase AC supply
Derating characteristic 6A model
Derating characteristic 9A model
Overtemperature trips
Connector locations
Front panel connectors
Top panel connectors
Ethernet
Power connections
Earthing / grounding
Protection class
Earth leakage
Single-phase or three-phase power connections
Location
Nominal input voltage
Input power conditioning
Power disconnect and protection devices
Supplying input power from a variac variable transformer
Recommended fuses, circuit breakers and wire sizes
Protection device and wire ratings
Drive overload protection
Catalog Cont Input Fuse Circuit Minimum Number
Power supply filters
Baldor filter part numbers
Harmonic suppression
Reversing the filter
8 24V control circuit supply
Nominal input
Voltage Range
Input current
Motor connections
AC supply voltage
Output voltage range
Motor circuit contactors
Motor cable pin configuration Baldor linear motors
Thermal switch Blue
Sinusoidal filter
Hall +5VDC
Thermal switch connection
Motor thermal switch circuit
Motor brake connection
Motor brake control circuit
Regeneration resistor Dynamic Brake resistor
Regeneration resistor connections
Basic Installation MN1942
Feedback
Incremental encoder feedback
Pin Incremental encoder function
Encoder cable connections rotary motors
Encoders without Halls
Halls-only feedback cable connections rotary motors
Encoder cable pin configuration Baldor linear motors
Hall U+ White Hall V+ Red Hall W+ Black +5V out
Hall GND
SSI feedback
Pin SSI function
SSI cable pin configuration
MicroFlex e100 Motor / cable Baldor SSI cable
+5V out Red Sense
Clock+
SinCos feedback
Pin SinCos function
SinCos cable pin configuration
MicroFlex e100 Motor / cable Baldor EnDat / SinCos
Sin+
Cos+
EnDat absolute encoder feedback
Pin Absolute encoder function
Absolute encoder cable pin configuration
Data
Data +
Feedback MN1942
AC input power and DC bus voltage
Effect of AC power supply voltage on DC-bus voltage
Effect of AC power supply voltage on DC-bus ripple
Effect of output current on DC-bus ripple voltage
Motor output power
2 24VDC control circuit supply input
Regeneration
Digital inputs drive enable and DIN0 general purpose
Digital inputs DIN1, DIN2 high speed general purpose
Digital outputs DOUT0, DOUT1 status and general purpose
Unit All models Type
Incremental encoder feedback option
SSI encoder feedback option
SinCos / EnDat encoder feedback option
Ethernet interface
Can interface
Environmental
Weights and dimensions
Specifications MN1942
Accessories
Fan tray FAN001-024 Dimensions
Fan tray
Assembled MicroFlex e100 and fan tray
Footprint filter single-phase only
Footprint filter
Dimensions mm inches
EMC filters
Catalog numbers
Rated amps
MN1942 Accessories A-5
Filter dimensions, type FI0029A00
Regeneration resistor dimensions
Regeneration resistors
Motor power cables
Motor power cable part numbers
Catalog number
025
Cable assembly description Catalog number Length
SSI feedback cables
Encoder / Hall feedback cables
Cable assembly description
EnDat absolute encoder and SinCos feedback cables
Feedback cable part numbers
CBL025SF-E2 Meaning Alternatives
Ethernet cables
Baldor catalog number Length
Accessories MN1942
Control System
Servo configuration
Control System B-3
Torque servo configuration
System B-5
Control System MN1942
Outline
EMC Conformity and CE marking
MicroFlex e100 compliance
EMC wiring technique
Use of CE compliant components
EMC installation suggestions
Wiring of shielded screened cables
Earthing/grounding cable shields
Index
Index MN1942
Supply filters, 3-16, A-4 using a variac
USB
Comments
Comment
Comments MN1942