LSI Specification | MB86617A |
<Flow chart for received data after storing in Asynchronous receive FIFO
<Host> | <Device> |
START
Issue Asynchronous receive(03h)
instruction.
Read 1 word of the data from receive Asynchronous data port
Read flag & status register.
1
data req bit
0
Issue Remove busy(04h)
instruction
Prepare for reading received data.
Read 1 word of received data and increment read pointer of receive buffer.
Receive Remove busy(04h) instruction.
Receive FIFO read mode completed.
recv busybit=0
END
Figure 11.4.2 Flow chart for received data after storing in Asynchronous receive FIFO
Note1: If the length of received data is below quadret digid, it is stored by quadret unit????.
Note2: CRC code is not included in the data.
Rev.1.0 | 124 | Fujitsu VLSI |