Fujitsu MB86617A INT7, INT8, INT9, INT10, INT11, INT12, INT13, INT14, INT15, INT16, INT17, INT18

Models: MB86617A

1 139
Download 139 pages 23.54 Kb
Page 115
Image 115

LSI Specification

 

MB86617A

 

 

 

 

 

 

Interrupt

Interrupt Item

Description

 

 

 

 

 

 

 

 

 

 

 

 

INT7

Isochronous cycle too long

Isochronous cycle exceeded specified time.

 

 

>Informs only if this node is Cycle master.

 

 

 

 

 

 

 

 

 

 

INT8

Bus occupancy violation

Node occupied longer time than MAX_DATA_TIME.

 

>Need to issue “Bus reset”.

 

 

 

 

 

 

 

 

 

 

 

INT9

Asynchronous packet received

Received Asynchronous packet addressed to

self-node normally, and

 

stored data at ASYNC receive specific buffer.

 

 

 

 

 

 

 

 

 

 

INT10

CPIF output header is no 47h (Transmit)

Header byte of source packet output from CPIF at transmitting

 

MPSG2 -TS is not ‘47h’.

 

 

 

 

>Valid only when transmitting MPSG2-TS.

 

 

 

 

 

 

INT11

Data length short error

Receive packet data length is shorter than data-length of packet header.

 

 

 

 

 

INT12

Data length long error

Receive packet data length is longer than data-length of packet header.

 

>Store only data indicated by data-length value to buffer.

 

 

 

 

 

 

 

 

 

 

 

Detected format error in packet received.

 

 

INT13

Packet format error

Occurred convention failure of packet format like Reserved range is not

 

‘0’.

 

 

 

 

 

 

 

 

>Delete packet received.

 

 

 

 

 

 

INT14

Header CRC error

Detected CRC error in the header of packet received.

 

>Delete packet received.

 

 

 

 

 

 

 

 

 

 

INT15

Data CRC error

Detected CRC error in the data range of packet received.

 

>Do not delete packet received.

 

 

 

 

 

 

 

 

 

 

 

INT16

Asynchronous receive FIFO full

ASYNC receive specific buffer is full.

 

 

>Delete following packet received.

 

 

 

 

 

 

 

 

 

 

INT17

Asynchronous packet send

Completed sending Asynchronous packet by issueing instruction.

 

 

 

 

 

INT18

Input CGMS or TSCH changed

CGMS or TSCH information input from TSP IC I/F was not consistent

 

with the souce packet input just before.

 

 

 

 

 

 

 

 

 

 

INT19

Acknowledge missing

Not returned Acknowledge packet in correspondance with Asynchronous

 

packet of non -broadcast sent from self-node within specified limit.

 

 

 

 

 

 

 

 

 

INT20

Acknowledge send

Completed sending Acknowledge packet.

 

 

 

 

 

 

 

INT21

Receive EMI or ODD/EVEN changed

Changede EMI data or ODD/EVEN value

of received Isochronous

 

packet.

 

 

 

 

 

 

 

 

 

 

INT22

First packet received

Received the first packet after setting receive ISO channel.

 

 

 

 

 

Rev.1.0

110

Fujitsu VLSI

Page 115
Image 115
Fujitsu MB86617A INT7, INT8, INT9, INT10, INT11, INT12, INT13, INT14, INT15, INT16, INT17, INT18, INT19, INT20, INT21