LSI Specification

MB86617A

7.9. Transmit Offset Setting Register [A]

Transmit offset setting register [A] is the register that sets offset value added to cycle-time-monitor value. Its aim is to generate source packet header (Time -stamp) added to transmit packet processed by bridge -Ach. (Max. 32 ms)

Time-stamp value is generated on the basis of cycle-time-monitor value at input of first byte of source packet from TSP -IC.

AD

 

R/W

Bit

Bit

 

Bit

 

Bit

Bit

Bit

Bit

Bit

Bit

Bit

Bit

 

Bit

Bit

 

Bit

Bit

Bit

 

15

14

 

13

 

12

 

11

10

9

8

7

6

5

 

4

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14h

R/W

 

 

 

 

 

 

 

 

reserved

 

 

 

 

 

 

transmit-offset-A (high)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16h

R/W

 

 

 

 

 

 

 

 

 

transmit-offset-A (low)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial Value

 

 

 

 

 

 

 

 

 

 

“0000 h”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIT

 

Bit Name

Action

 

Value

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

-

Always indicate ‘0’.

 

 

 

 

 

 

 

 

 

 

15 - 4 (high)

reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

-

Always write in ‘0’.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 - 0 (high)

 

 

 

 

 

 

 

 

Set value to be added to cycle-count range of cycle-time-monitor.

 

 

 

15 - 12 (low)

 

 

 

 

 

 

 

 

Setting range is 0h to FFh. (unit=125μS).

 

 

 

 

 

 

 

 

 

transmit-offset

 

Read/

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-A

 

Write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 - 0

 

 

 

 

 

 

 

 

Set value to be added to cycle-offset range of cycle -time-monitor.

 

 

 

 

 

 

 

 

 

 

 

Setting range is 0h to C00h. (unit=1/24.576 MHz).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev.1.0

39

Fujitsu VLSI

Page 44
Image 44
Fujitsu MB86617A manual Transmit Offset Setting Register a