[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce IMMediate TIMer INTernal2

Sets or queries the stop arm for Time Interval measurements.

Query Response A sequence of ASCII-encoded bytes: IMM or TIM or INT2

Comments ∙ *RST: IMMediate

The [:SENS]:TINT:ARM:ESTOP[:LAYer[1]]:SOUR command has no affect on the following measurements: Risetime, Falltime, Duty Cycle, and Pulse Width.

Related Gate & ExtArm

Front-Panel

Keys

[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:TIMer <numeric_value> [S]

Sets or queries the time used to delay the stop arm for Time Interval measurements.

<numeric_value> Range

<numeric_value> Resolution

Query Response

Comments

For short delay: 100E-9 to 0.999,999,9 seconds

For long delay: 1.00 0 to 10.000 seconds

For short delay: 100E-9 seconds

For long delay: 1E -3 seconds

Numeric data transferred as ASCII bytes in <NR1> format.

*RST: 100E-9 S

Only applies when [:SENS]:TINT:ARM:ESTOP[:LAYer[1]]:SOUR TIM is selected.

The [:SENS]:TINT:ARM:ESTOP[:LAYer[1]]:TIM command has no affect on the following measurements: Risetime, Falltime, Duty Cycle, and Pulse Width.