recommended selection is Auto and it is the default setting. To disable Flow Control, select Disable from the Value list on the Advanced tab.
oAuto. (Default) Auto detect flow control
oDisable. PAUSE frame receipt and transmission is disabled
oTx PAUSE. PAUSE frame transmission is enabled
oRx PAUSE. PAUSE frame receipt is enabled
Rx/Tx PAUSE. PAUSE frame receipt and transmission is enabled
NOTE: User control of Flow Control parameter is not available for NC71xx adapters.
•Link Speed & Duplex. Allows the user to set the connection speed to the network and mode. Full- Duplex Mode allows the adapter to transmit and receive network data simultaneously. This property is not available for NC310F and NC61xx adapters through the Microsoft® User Interface.
oDefault = Auto Detect
oRange = NC340x and NC71xx Adapters: Auto Detect;
•Locally Administered Address. Specifies the
oDefault = Not Present
oRange = Value; Not Present
•Number of Receive Descriptors. Specifies the number of buffers used by the driver when copying data to the protocol memory. In high network load situations, increasing receive descriptors can increase performance. The tradeoff is that this also increases the amount of system memory used by the driver. If too few receive buffers are used, performance suffers. If too many receive buffers are used, the driver unnecessarily consumes memory resources.
oDefault
NC110x, NC310F, NC340x, NC360x, NC364x, NC6170, and NC7170 = 256
All others = 160
oRange
NC6132, NC6133, and NC6134 =
NC310F, NC340x, NC6170, and NC7170 =
•Number of Transmit Descriptors. Specifies the number of resources allocated to transmit packets.
oDefault = 256
oRange
NC6132, NC6133, and NC6134 =
NC310F, NC340x, NC6170, and NC7170 =