Server Access

: Initial value

Item

Preset Values

Description

Server Access

 

Server access

Server name

 

 Server

For specifying the server name.

 

 

 

 

 

 

 

 

Local port

 80

For specifying the port number to use for the server.

 

 

 

 

 

 

 

 

Enable internet

 

Select check box

Select this check box to enable access to this unit from a

 

 

access

 

 Do not select

surveillance computer connected to the Internet via the

 

 

 

 

check box

router or firewall.

 

 

 

 

 

If you have selected this option, specify the global IP

 

 

 

 

 

address in the Internet address field for the Internet router

 

 

 

 

 

or firewall, and the port number in the Internet port field for

 

 

 

 

 

access to the Internet by the surveillance computer. You

 

 

 

 

 

have to configure an appropriate port forwarding on the

 

 

 

 

 

router or firewall to allow access by a surveillance

 

 

 

 

 

computer that is connected to the Internet.

 

 

 

 

 

For details, refer to the relevant instruction manuals of the

 

 

 

 

 

respective devices.

 

 

 

 

 

 

 

 

Internet address

^

For specifying the global IP address or host name when

 

 

 

 

 

connecting to this unit via the Internet.

 

 

 

 

 

 

 

 

Internet port

^

For specifying the port number to use when connecting to

 

 

 

 

 

this unit via the Internet.

 

 

 

 

 

 

 

 

Max. number of

 11

For specifying the maximum number of Smart Client users

 

 

clients

 

 

who can connect to the system at the same time. Those

 

 

 

 

 

who use the Smart Client on the live display and playback

 

 

 

 

 

display of this unit are also included in the users. Do not

 

 

 

 

 

specify 11 or higher.

 

 

 

 

 

 

Local IP Ranges

 

 

 

 

 

 

 

 

 

 

 

Local IP ranges

Start Address

 

Validate access to this unit from the internet, and set when connection to this unit

 

 

 

 

from a surveillance computer within the local network is necessary. Click [Add],

 

 

End Address

 

 

 

 

 

and specify the IP address range of the surveillance computer. The IP address

 

 

 

 

range can be set for only when it is necessary.

 

 

 

 

You may specify only one IP address. (Example: 192.168.10.1 to

 

 

 

192.168.10.1)

 

 

 

 

 

 

 

 

Language Support and

XML Encoding

 

 

 

 

 

 

 

 

 

Language support

Language

 

For selecting the language used for the camera name, user name, and password

 

 

 

 

(local character set).

 

 

 

 

 

Arabic (864) (IBM864)

 

 

 

 

Arabic (ASMO 708) (ASMO-708)

 

 

 

 

Western European (DOS) (ibm850)

 

 

 

 

Western European (IA5) (x-IA5)

 

 

 

 

 Western European (ISO) (iso-8859-1)

 

 

 

 

Western European (Mac) (macintosh)

 

 

 

 

Western European (Windows) (Windows-1252)

Caution:

Make sure to set this item to [Western European(ISO)(iso-8859-1)] before use. Use with a language other than [Western European(ISO)(iso-8859-1)] will cause a failure.

111

Page 117
Image 117
JVC VR-X1600U, VR-X3200U manual 111, Server Access,  Server,  Western European ISO iso-8859-1