DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

Register Name:

SU.MACFCR

 

 

 

 

 

 

 

Register Description:

MAC Flow Control Register

 

 

 

 

 

Register Address:

001Ch (indirect)

 

 

 

 

 

001Ch:

 

 

 

 

 

 

 

 

 

 

 

Bit #

31

30

 

29

28

 

27

26

25

24

 

Name

PT15

PT14

PT13

PT12

 

PT11

PT10

PT09

PT08

Default

0

0

 

0

0

 

0

0

0

0

 

001Dh:

 

 

 

 

 

 

 

 

 

 

 

Bit #

23

22

 

21

20

 

19

18

17

16

 

Name

PT07

PT06

PT05

PT04

 

PT03

PT02

PT01

PT00

Default

0

1

 

0

1

 

0

0

0

0

 

001Eh:

 

 

 

 

 

 

 

 

 

 

 

Bit #

15

14

 

13

12

 

11

10

09

08

 

Name

Reserved

Reserved

Reserved

Reserved

 

Reserved

Reserved

Reserved

Reserved

Default

0

0

 

0

0

 

0

0

0

0

 

001Fh:

 

 

 

 

 

 

 

 

 

 

 

Bit #

07

06

 

05

04

 

03

02

01

00

 

Name

Reserved

Reserve

 

Reserved

Reserved

 

Reserved

Reserved

FCE

FCB

 

Default

 

d

 

 

 

 

 

 

 

 

 

0

0

 

0

0

 

0

0

1

0

 

Bits 16 - 31: Pause Time (PT[00:15]) These bits are used for the Pause Time Field in transmitted Pause Frames. This value is the number of time slots the remote node should wait prior to transmission.

Bit 1: Flow Control Enable (FCE) When set to 1, the MAC automatically detects pause frames and will disable the transmitter for the requested pause time.

Bit 0: Flow Control Busy (FCB) The host can set this bit to 1 in order to initiate transmission of a pause frame. During transmission of a pause frame, this bit remains set. The DS33R11 will clear this bit when transmission of the pause frame has been completed. The user should read this bit and ensure that this bit is equal to zero prior to initiating a pause frame.

190 of 344

Page 190
Image 190
Maxim DS33R11 specifications Su.Macfcr