DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver

10.14 T1 Bit-Oriented Code (BOC) Controller

The transceiver contains a BOC generator on the transmit side and a BOC detector on the receive side. The BOC function is available only in T1 mode.

10.14.1 Transmit BOC

Bits 0 to 5 in the TR.TFDL register contain the BOC message to be transmitted. Setting TR.BOCC.0 = 1 causes the transmit BOC controller to immediately begin inserting the BOC sequence into the FDL bit position. The transmit BOC controller automatically provides the abort sequence. BOC messages are transmitted as long as TR.BOCC.0 is set.

10.14.1.1 Transmit a BOC

1)Write 6-bit code into the TR.TFDL register.

2)Set the SBOC bit in TR.BOCC = 1.

10.14.2 Receive BOC

The receive BOC function is enabled by setting TR.BOCC.4 = 1. The TR.RFDL register now operates as the receive BOC message and information register. The lower six bits of the TR.RFDL register (BOC message bits) are preset to all 1s. When the BOC bits change state, the BOC change-of-state indicator, TR.SR8.0, alerts the host. The host then reads the TR.RFDL register to get the BOC status and message. A change-of-state occurs when either a new BOC code has been present for a time determined by the receive BOC filter bits RBF0 and RBF1 in the TR.BOCC register, or a nonvalid code is being received.

10.14.2.1 Receive a BOC

1)Set integration time through TR.BOCC.1 and TR.BOCC.2.

2)Enable the receive BOC function (TR.BOCC.4 = 1).

3)Enable interrupt (TR.IMR8.0 = 1).

4)Wait for interrupt to occur.

5)Read the TR.RFDL register.

6)If TR.SR2.7 = 1, then a valid BOC message was received. The lower six bits of the TR.RFDL register comprise the message.

91 of 344

Page 91
Image 91