Technical Configuration (Analog/BRI)

MultiVOIP User Guide

 

 

E&M Interface Parameter Definitions

Field Name

Values

Description

Interface

E&M

enables E&M functionality

 

 

 

Type

Types 1-5. Each

Refers to the type of E&M

 

type can be 2-wire

interface being used.

 

or 4-wire.

 

 

 

 

Signal

Dial Tone or

When Dial Tone is selected, no

 

Wink

wink is required on the E lead or M

 

 

lead in the call initiation or setup.

 

 

When Wink is selected, a wink is

 

 

required during call setup.

 

 

 

Wink Timer

integer values,

This is the length of the wink for

(in ms)

in milliseconds

wink signaling.

 

 

Applicable only when Signal

 

 

parameter is set to “Wink.”

 

 

 

Pass Through

Y/N

When enabled (“Y”), this feature is

 

 

used to create an open audio path

 

 

for 2- or 4-wire. The E&M leads

 

 

are passed through the voip

 

 

transparently.

 

 

Applicable only for E&M

 

 

Signaling with Dial Tone.

 

 

 