MultiVOIP User Guide

Technical Configuration (Digital Voips)

 

 

 

 

 

 

 

 

 

Voice/Fax Parameter Definitions (cont’d) )

 

 

 

 

 

Field Name

Values

Description

 

 

 

 

 

Auto Disconnect

 

 

 

 

 

 

Automatic

--

The Automatic Disconnection group

 

Disconnect-

 

provides four options which can be

 

ion

 

used singly or in any combination.

 

 

 

 

 

Jitter Value

1-65535

The Jitter Value defines the average

 

 

milli-

inter-arrival packet deviation (in

 

 

seconds

milliseconds) before the call is

 

 

 

automatically disconnected. The default

 

 

 

is 150 milliseconds. A higher value

 

 

 

means voice transmission will be more

 

 

 

accepting of jitter. A lower value is less

 

 

 

tolerant of jitter.

 

 

 

Inactive by default. When active,

 

 

 

default = 150 ms. However, value must

 

 

 

equal or exceed Dynamic Minimum

 

 

 

Jitter Value.

 

 

 

 

 

Call Duration

1-65535

Call Duration defines the maximum

 

 

seconds

length of time (in seconds) that a call

 

 

 

remains connected before the call is

 

 

 

automatically disconnected.

 

 

 

Inactive by default.

 

 

 

When active, default = 180 sec.

 

 

 

This may be too short for most

 

 

 

configurations requiring upward

 

 

 

adjustment.

 

 

 

 

 

Consecutive

1-65535

Consecutive Packets Lost defines the

 

Packets Lost

 

number of consecutive packets that are

 

 

 

lost after which the call is automatically

 

 

 

disconnected.

 

 

 

Inactive by default.

 

 

 

When active, default = 30

 

 

 

 

 

Network

1 to 65535

Specifies how long to wait before

 

Discon-

seconds;

disconnecting the call when IP network

 

nection

Default =

connectivity with the remote site has

 

 

300 sec.

been lost.

 

 

 

 

145

Page 145
Image 145
Multi-Tech Systems MVP-2410, MVP-2400, MVP-3010 manual Automatic Disconnection group, Consecutive Packets Lost defines, 145